Sankosha Y08JS-Series Gas Tube Arresters |
 |
Applications:
Cable Telephony Products
Modems/Cable Modems
Broadband/CATV/Coaxial Protectors
xDSL Modems and Peripherals
Building Entry/Outside Plant
Transient Voltage Surge Suppression
|
Features:
High Surge Current Rating
Non-Radioactive
RoHS Compliant (100% Lead-Free)
ISO 9001 Certified
High Insulation Resistance(1)
Low Capacitance ≤ 1.5pF
|
 |
Part Number |
DC Breakdown Voltage |
Impulse Breakdown Voltage |
DC Holdover Voltage V(2) |
Impulse Life 10/1000μs 100A |
Impulse Discharge Current 8/20μs |
AC Discharge Current 50 Hz |
| 100V/s |
100V/μs |
1kV/μs |
1 Time |
10 Times(5) |
9 Cycles 1 Time |
1 Second |
| Y08JS-90B |
70-108V |
≤ 450V |
≤ 500V |
≤ 52V |
300 Times |
20 kA |
15 kA |
90 A |
20A, 10 Times |
| Y08JS-230B |
184-280V |
≤ 600V |
≤ 700V |
≤ 52V |
300 Times |
20 kA |
15 kA |
90 A |
20A, 10 Times |
| Y08JS-230AF1(3,4) |
184-280V |
≤ 600V |
≤ 700V |
≤ 52V |
300 Times |
20 kA |
15 kA |
90 A |
20A, 10 Times |
| Y08JS-350B |
280-420V |
≤ 700V |
≤ 800V |
≤ 52V |
300 Times |
20 kA |
15 kA |
90 A |
20A, 10 Times |
Notes:
- Insulation Resistance for all part numbers is ≥ 10,000 MΩ measured at:
DC 50V for the Y08JS-90
DC 100V for the Y08JS-230 and Y08JS-350
- DC Holdover Voltage measured in accordance with the ITU-T K.12 or the IEEE C62.31-1987 Test Circuit
- Fail-Safe Operation Time at 50 Hz:
0.7A: 210 seconds
2.0A: 60 seconds
7.0A: < 6 seconds
- The Fail Safe device in Model Y08JS-230AF1 is not lead-free.
- Five times each polarity
- Capacitance measured at 1 MHz is ≤ 1.5 pF for the Y08JS-90B, Y08JS-230B and Y08JS-350B and ≤ 3.5 pF for the Y08JS-230AF1
- Custom Configurations Available
|
|