Sankosha SD4-Series Gas Tube Arresters |
 |
Applications:
Cable Telephony Products
Modems/Cable Modems
Broadband/CATV/Coaxial Protectors
xDSL Modems and Peripherals
Building Entry/Outside Plant
Transient Voltage Surge Suppression
|
Features:
UL 497B Recognized (File E140906)
High Surge Current Rating
Non-Radioactive
RoHS Compliant (100% Lead-Free)
ISO 9001 Certified
Low Capacitance ≤ 0.5pF
Proven Performance
|
 |
Part Number |
DC Breakdown Voltage(1) |
Impulse Breakdown Voltage |
Insulation Resistance MΩ(2) |
DC Holdover Voltage V(4) |
Impulse Life |
Impulse Discharge Current 8/20μs 1 Time |
AC Discharge Current 50Hz |
| 100V/s |
1KV/μs |
8/20μs, 100A |
10/1000μs, 50A |
1 Second |
| SD4-75 |
75V |
≤ 600V |
≥ 10,000 |
≤ 52V |
300 Times |
n/a |
2.5 kA |
5A, 1 Time |
| SD4-90 |
90V |
≤ 600V |
≥ 10,000 |
≤ 52V |
300 Times |
n/a |
2.5 kA |
5A, 1 Time |
| SD4-145 |
145V |
≤ 600V |
≥ 10,000 |
≤ 80V |
300 Times |
n/a |
2.5 kA |
5A, 1 Time |
| SD4-200 |
200V |
≤ 600V |
≥ 10,000 |
≤ 135V |
300 Times |
n/a |
2.5 kA |
5A, 1 Time |
| SD4-230 |
230V |
≤ 650V |
≥ 10,000 |
≤ 135V |
n/a |
300 Times |
2.5 kA |
5A, 1 Time |
| SD4-350(3) |
350V |
≤ 700V |
≥ 10,000 |
≤ 135V |
n/a |
300 Times |
2.5 kA |
5A, 1 Time |
| Notes: |
- DC Breakdown Voltage Ranges are ± 20%
- Insulation Resistance measured at:
DC 50V for the SD4-75, SD4-90 and SD4-145
DC 100V for the SD4-200, SD4-230 and SD4-350
- The SD4-350 is not currenly UL Recognized.
- DC Holdover Voltage measured in accordance with the ITU-T K.12.
- Capacitance measured at 1 MHz for all part numbers is ≤ 0.5 pF
- Available on tape and reel
|
|
|
|