/* Navigation Bar Contents */
English | Español
3SD4-Series
Sankosha Gas Discharge Tubes (GDT) - Surge Arresters
Applications:

  • Cable Telephony Products
  • Modems/Cable Modems
  • Broadband/CATV/Coaxial Protectors
  • xDSL Modems and Peripherals
  • Building Entry/Outside Plant
  • Transient Voltage Surge Suppression
  • Features:

  • UL 479B Recognized (File E140906)
  • High Surge Current Rating
  • Non-Radioactive
  • Surface Mount
  • Small Size
  • RoHS Compliant (100% Lead-Free)
  • ISO 9001 and ISO 14001 Certified
  • Low Capacitance ≤ 1.0pF

  • Part
    Number
    DC Breakdown Voltage
    (L1-E)(L2-E)
    Impulse Breakdown Voltage
    (L1-E)(L2-E)
    Insulation Resistance(1) DC Holdover Voltage(2) Impulse Life
    (L1+L2-E)
    Impulse Discharge Current (L1+L2-E) (8/20μs) AC Discharge Current (L1+L2-E) (50Hz)
    100V/s 1kV/μs 8/20μs 200A 10/1000μs 100A 1 Second
    3SD4-75 75V ±20% ≤ 600V ≥ 10,000 MΩ ≤ 52V 1000 Times 5kA 10A
    3SD4-90 90V ±20% ≤ 600V ≥ 10,000 MΩ ≤ 52V 1000 Times 5kA 10A
    3SD4-145 145V ±20% ≤ 600V ≥ 10,000 MΩ ≤ 80V 1000 Times 5kA 10A
    3SD4-200 200V ±20% ≤ 600V ≥ 10,000 MΩ ≤ 135V 1000 Times 5kA 10A
    3SD4-230 230V ±20% ≤ 650V ≥ 10,000 MΩ ≤ 135V 300 Times 10kA 10A


    Notes:
    1. Insulation Resistance for all part numbers is ≥ 10,000 MΩ measured at:
            DC 50V for the 3SD4-75, 3SD4-90 and 3SD4-145
            DC 100V for the 3SD4-200 and 3SD4-230
    2. DC Holdover Voltage measured in accordance with the ITU-T K.12 or the IEEE C62.31-1987 Test Circuit
    3. Capacitance measured at 1 MHz for all part numbers is ≤ 1.0 pF
    Home     Arresters     Grounding     LAN     Coaxial     GlobalSpec     Contact Us     About Sankosha
    Sankosha U.S.A., Inc.,    406 Amapola Avenue, Suite 135,    Torrance, CA 90501,    USA
    Phone Toll Free: (888) 711-2436    Phone: (310) 320-1661    Fax: (310) 618-6869    Email: sales@sankosha-usa.com

    Copyright © 2023 Sankosha U.S.A., Inc. All rights reserved.